[. . . ] If this does not happen after 2 minutes, the batteries will need to be removed from both units and reset from step 1. In order to ensure sufficient 868 MHz transmission however, this should under good conditions be a distance no more than 80 meters between the final position of the Temperature Station and the transmitter (see notes on "Positioning" and "868 MHz Reception"). HOW TO INSTALL AND REPLACE BATTERIES IN THE TEMPERATURE STATION The Temperature Station uses 2 x AA, IEC LR6, 1. 5V batteries. When batteries will need to be replaced, the low battery icon will appear on the LCD. To install and replace the batteries, please follow the steps below: 1. [. . . ] Press the + key to adjust the hour (press and hold to allow fast advance). Press the + key to adjust the minute (press and hold to allow fast advance). Press SET key once more to return to normal display. Note: If no buttons are pressed within approximately 8 seconds while in setting mode, the unit will return to normal operating mode. VIEWING THE INDOOR TEMPERATURE AND MIN/MAX The indoor temperature is displayed in the second section of the LCD along with the indoor MIN/MAX records: 26 Indoor temperature MIN indoor temperature MAX indoor temperature Note: · The maximum temperature record for the MIN indoor temperature can only be up to -10ºC, and the MIN/MAX temperature resolution is 1° C. · The resolution of the indoor temperature is 0. 5ºC VIEWING THE OUTDOOR TEMPERATURE AND THE MIN/ MAX The outdoor temperature is displayed in the last section of the LCD along with the outdoor MIN/MAX records: Outdoor temperature MIN outdoor temperature MAX outdoor temperature 27 Note: · The minimum/maximum temperature resolution is 1° C. · The resolution of the outdoor temperature is 0. 1ºC TO RESET THE MIN/MAX DATA: The MIN/MAX temperature can be reset manually by pressing and holding the + key for about 3 seconds. This will reset all indoor and outdoor MIN/MAX temperature to current indoor and outdoor temperatures. LOW BATTERY INDICATOR Low battery indicator is displayed on the LCD when the batteries require changing. 868 MHz RECEPTION CHECK The Temperature Station should receive the outdoor temperature data within a few minutes after setup. If the temperature data are not received about 2 minutes after setup (the signal reception icon does not appear), please check the following points: 1. The distance of the Temperature Station or transmitter should be at least 1. 5 to 2 meters away from any interfering sources such as computer monitors or TV sets. Avoid positioning the Temperature Station onto or in the immediate proximity of metal window frames. Using other electrical products such as headphones or speakers operating on the same signal frequency (868MHz) may prevent correct signal transmission and 28 4. reception. Neighbors using electrical devices operating on the 868MHz signal frequency can also cause interference. Note: When the 868MHz signal is received correctly, do not re-open the battery cover of either the transmitter or the Temperature Station, as the batteries may spring free from the contacts and force a false reset. If this happens accidentally, all units must be reset (see Setting up above) otherwise transmission problems may occur. The transmission range is about 80 m from the transmitter to the Temperature Station (in open space). However, this depends on the surrounding environment and interference levels. If no reception is possible despite the observation of these factors, all system units have to be reset (see Setting up above). POSITIONING THE TEMPERATURE STATION: Table standing The Temperature Station comes attached with a table stand, which provides the option of table standing the unit in addition to wall mounting. 29 To wall mount: Before wall mounting, please check that the outdoor temperature values can be received from the desired locations: 1. Fix a screw (not supplied) into the desired wall, leaving the head extended out by about 5mm. [. . . ] Do not expose the units to extreme and sudden temperature changes, this may lead to rapid changes in forecasts and readings and thereby reduce their accuracy. SPECIFICATIONS: Temperature measuring range Indoor : -9. 5ºC to +59. 5ºC with 0. 5ºC resolution ("OF. L" displayed if outside this range) Outdoor : -39. 9ºC to +59. 9ºC with 0. 1ºC resolution ("OF. L" displayed if outside this range) Indoor Temperature checking interval : every 20 seconds Outdoor data checking interval : every 8 seconds Power consumption 2 x AA, IEC LR6, 1. 5V Temperature Station : Outdoor Temperature Transmitter : 2 x AAA, IEC LR3, 1. 5V Battery life cycle (Alkaline batteries recommended): Temperature Station : approximately 24 months Outdoor Temperature Transmitter : approximately 12 months 32 Dimensions (L x W x H) Temperature Station : Outdoor Temperature Transmitter : 79. 8 x 29 x 127mm 32. 4 x 14. 1 x 86. 5mm LIABILITY DISCLAIMER: · The electrical and electronic wastes contain hazardous substances. Disposal of electronic waste in wild country and/or in unauthorized grounds strongly damages the environment. · Please contact your local or/and regional authorities to retrieve the addresses of legal dumping grounds with selective collection. User shall take an active part in the reuse, recycling and recovery of the electrical and electronic waste. [. . . ]